What is a studor vent on a toilet?

The official name of studor vent is Air Admittance Valve. Air Admittance Valve or studor vent is a special kind of venting system that can be found in the plumbing structure of a building.

Studor vent is often used in the plumbing structure of a toilet too for its special features.

The main feature of a student vent is that it is able to permit air room in the drainage pipe of the toilet. When the flow of water inside the toilet pipe stops, the studor vent stops the sewer gasses from coming into the building with the help of the studor vent.

The studor vent on a toilet can be a good addition if the route to the venting system is blocked due to some reason. The studor vent is also quite affordable compared to other venting systems.

Can you vent a toilet with a studor vent?

It is quite possible to vent a toilet with a studor vent. A studor vent AKA air admittance valve is legal according to international building and plumbing codes. The best thing about a studor vent is its affordability. The easy maintenance is another key feature of a studor vent.

There is nothing illegal about venting a toilet with a studor vent. If you manage to follow the general building and plumbing codes, then you should be able to use a studor vent in your toilet. Studor vent is quite cost effective too because of its simple structure.

However, you can contact your local authority to know if it is permitted by them to use a studor vent in your area. Studor vents can work wonders if you are facing difficulties to install the traditional vent in your toilet.

Using a studor vent in the toilet also makes the roof maintenance easy. Installing a studor vent is simple as it does not require a lot of materials like the normal venting system.

Studor vent can be a wise choice if you are worried about cost and maintenance.

Are studor vents legal?

Studor vents are legal according to some of the most important building codes in the USA. The list of codes includes International Plumbing Code, International Residential Code, Uniform Plumbing Code, and National Standard Plumbing Code.

If you use the studor vent by maintaining these building and plumbing codes, then you will not be charged with illegal venting system.

However, the local building codes of a state can often make studor vents legal. So it is better to contact your local authority about the legality of a studor vent before installing one in your building.

5 reasons why you can vent a toilet with a studor vent

There are a lot of reasons that allow you to vent a toilet with a studor vent. Let’s discuss in detail about them.

Legality:

The most crucial thing about studor vent is that it is legal according to several international building and plumbing codes.

So you cannot install a studor vent in your toilet without worrying about getting a legal notice from the concerned authority. You will need to adhere to the general plumbing codes in order to install the studor vent on a toilet.

Alternative:

Studor vents work as an easy and effective alternative to a normal vent. Sometimes the inability to connect the toilet vent to the main venting system can call for the need of a studor vent.

The studor vent can solve this problem easily due to its one-way venting mechanism.

Effectiveness:

Studor vents are very effective as a venting system in the toilet. The main purpose of a studor vent is to interrupt the sewer gasses from entering into your home and office.

Affordable:

Studor vent is an easy-going venting system that does not require complex design and structure. This means that you do need to buy a lot of things to build a studor vent inside the toilet. That makes studor vents incredibly affordable.

Easy maintenance:

Due to its simple structure, studor vent is very easy to maintain. You do not have to work on the roof to install the studor vent in the toilet which reduces the list of maintenance.

If you are looking for an efficient venting system at an affordable price, then studor vent is a wise choice for you.

What is code for venting a toilet?

There are a lot of codes available when it comes to venting a toilet. One of the codes suggest that you have to use PVC pipes for the toilet vent with a diameter of two inches. This code is given by UPC (Uniform Plumbing Code).

On the other hand, the International Plumbing Code suggest you to use a pipe with a diameter of just one and a half inch.

Another important code of Uniform Plumbing code suggest that there should be a minimum of six feet distance between the trap and the toilet vent.

If you manage to adhere to these general codes, then you will not face any legal problem when it comes to venting your toilet.

How to vent a toilet with a studor vent?

Venting a toilet with a studor vent might seem like a daunting task if you do not have any prior experience regarding the matter. However, there are some steps and methods you can follow to accomplish this task. Let’s discuss in detail about some of them.

Gather the components:

First of all, you will need to gather the needed components for installing the studor vent. The list of the needed components include PVC tee fitting, cutters, male fitting, glue, reducer, pipe, pliers, pipe thread compound, and rag.

Attach the tee fitting:

You will need to make insertion on the drain line with the help of a hacksaw. The shape of the cut has to be square. Then you will have to attach the PVC tee fitting onto the drain line using PVC glue only.

Attach the reducer:

Next, you will be required to attach the reducer in the PVC tee fitting with the help of glue.

Install the vent:

This is the most important step ad you will need to attach the PVC pipe in the tee fitting through the toilet’s trap. The PVC cutters can help you to cut the pipe. Then, you will have to attach the PVC male fitting onto the PVC using glue.

You will be required to use the pipe thread compound to cover the threads of the male fitting properly.

In the next step, the Air Admittance valve AKA the studor valve has to be put in the PVC male fitting. A set of pliers will be helpful in this step. The extra pipe thread compound has to be put out using a rag.

What is the proper way to vent a toilet?

Many of us do not know about the proper way to vent a toilet. Let’s discuss in detail about it.

Location of the toilet:

The location of your toilet is pretty crucial when it comes to venting it. The distance between your toilet and the main drain line has to be six feet only. The diameter of the main drain pipe has to be three inches.

Attach the toilet pipe:

In the next step, you will have to attach the toilet pipe to the main drain line with glue. A hacksaw can be helpful when it comes to cutting the toilet pipe. A PVC tee fitting will be crucial in this step for connecting the toilet pipe and the main drain line.

Supporting structure:

Supporting structure has to be provided if the distance between the toilet and the main drain line is too much. PVC reducers come in handy as supporting structure.

Attach the vent pipe:

You will have to attach the vent pipe into the main venting system with the help of a Tee fitting. Glue will be helpful for this step.

Check the vent:

Next, you will need to flush the toilet to find out if the vent instillation is successful or not. You will have to look for leaks in the venting system. If you find leaks in the system, then you will have to contact a plumber to rectify the situation.

Final Thoughts

A studor vent can be used to vent a toilet. However, one should contact the local authority about the legality of studor vents in his area. A studor vent can be helpful when it comes to complex plumbing system. It also cuts down the installation process due to needing fewer materials.